Hierbij het overzicht van de geactualiseerde datasheets.
De belangrijkste zijn te vinden op deze website. Direct en eenvoudig te zoeken en te downloaden.
Normen & Voorschriften (meest relevante)
DS 1-15 | Roof-Mounted Solar Photovoltaic Panels | Interim revision. • Added guidance related to the recommended wind Importance Factor (IF). • Guidance related to minimum and maximum roof slopes has been clarified. • Added recommendations related to fire concerns, as supported by loss experience. |
DS 1-17 | Reflective Wall and Ceiling Insulation (new title) | Full revision. • The title was changed to “Reflective Wall and Ceiling Insulation.” • Removed guidance for non-FM Approved reflective insulations installed at existing buildings. |
DS 1-22 | Maximum Foreseeable Loss | Interim revision. • Minor editorial changes were made. |
DS 1-34 | Hail Damage | Interim revision. • Minor editorial changes were made to the legends on Figures C-1, D-1 and D-2. • Added guidance on selecting skylights and heat and smoke vents with VSH and SH+ ratings. See Appendix A for details. |
DS 1-35 | Vegetative Roof Systems, Occupied Roof Areas & Decks (new title) | Interim revision. • The title was changed to “Vegetative Roof Systems, Occupied Roof Areas and Decks.” • Added guidance for growth media when the windspeed is greater than or equal to 100 mph (63 m/s). • Added guidance for intensive vegetative roof systems including decks and when areas are elevated above the roof assembly. |
DS 1-42 | Maximum Foreseeable Loss Limiting Factors | Interim revision. • A recommendation has been added to avoid mass engineered timber as part of an MFL wall. |
DS 1-44 | Damage-Limiting Construction | Interim revision. • Minor editorial changes were made. |
DS 2-81 | Fire Protection System Inspection, Testing and Maintenance | Interim revision. • Clarified the required testing frequency of manual fire protection system control valves in Section 2.4.2 and Table 3. • Added references to the installation and acceptance testing data sheets for special protection systems. • Incorporated inspection, testing and maintenance guidance from Data Sheet 4-12, Foam Extinguishing Systems, Section 2.7 into Section 2.11.3. |
DS 3-11 | Flow and Pressure Regulating Devices for Fire Protection Service | Interim revision. • Renamed Section 2.3 to Protection. • Relocated existing sections 2.2.2 and 2.2.3 to Section 2.3, Protection. • Updated installation guidance for pressure reducing valves in system designs. |
DS 4-12 | Foam Extinguishing Systems | Interim revision. • Modified recommendations in Section 2.4.3, Foam Concentrate to address the application of Synthetic Fluorine Free Foam (SFFF) and Alcohol-Resistant Synthetic Fluorine Free Foam (AR-SFFF) when protecting non-polar (hydrocarbons) and polar (water-miscible) ignitable liquids. • Provided viscosity information in Section 2.5.4, Foam Concentrate Proportioners and Section 3.4.5, Foam Concentrate Proportioning Methods. • Revised Table 4 of Section 2.6.4.17, Alternate Test Methods to include NoFoam, La Jolla, California, USA and the Vector Fire Technologies, Tucson, Arizona, USA locations. |
DS 5-3 | Hydroelectric Power | Interim revision. • Minor editorial changes were made. |
DS 5-12 | Electric AC Generators | Interim revision. • Minor editorial changes were made. |
DS 5-25 | High Voltage Direct Current Converter Stations | Interim revision. • Minor editorial changes were made. |
DS 5-32 | Data Centers and Related Facilities | Interim revision. • Updated recommendations in Section 2.4.4 to allow equipment using Li-ion batteries in distributed power systems of data processing equipment to be protected with automatic water mist systems. • Made editorial updates to figures in Section 2.8.1, Electrical Distribution System and Section 3.4.1, Electrical Power Distribution. |
DS 6-17 | Rotary Kilns and Dryers | Interim revision. • Minor editorial changes were made. |
DS 7-4 | Paper Machines and Pulp Dryers | Interim revision. • Added allowance for loss of compressed air interlock for a closed shoe press/calender. • Revised oil and fluid selection for machine oil systems. • Replaced bulk oil release concept with specific oil hazard protection methodologies along with associated scenario and LE guidance. |
DS 7-20 | Oil Cookers | Interim revision. • Revised guidance in Section 2.4.2.5 for the water supply duration for FM Approved water mist systems used on oil cookers with an oil depth greater than 5 in. (13 cm). • Added guidance in Section 2.9.1 for power supplies for water mist systems and foam concentrate pumps. |
DS 7-29 | Ignitable Liquid Storage in Portable Containers | Interim revision. • Added protection guidance in Table 2.4.7.1 for the rack storage of liquids with a flash point < 200°F (93°C) in 5 oz. (150 ml) or less plastic containers. • Added protection guidance for glycerin. • Added protection guidance for rack storage of very high flash point liquids stored in composite intermediate bulk containers (IBCs) on plastic pallets. |
DS 7-39 | Lift Trucks | Interim revision. • Updated guidance for li-ion battery powered trucks. • Updated the definition for ignitable liquids to align with Data Sheet 7-32, Ignitable Liquid Operations. |
DS 7-54 | Natural Gas and Gas Piping | Interim revision. • Added recommendations for location of compressed natural gas supply trailers and modules (Section 2.2.15). |
DS 7-106 | Ground-Mounted Solar Photovoltaic Power | Interim revision. • Added guidance for separation between solar arrays and fire exposures. • Added guidance for construction of ancillary buildings. • Added guidance for fire department access. |
DS 7-110 | Industrial Control Systems | Interim revision. • Clarified fire protection recommendations. • Clarified ICS management recommendations. • Clarified and modified ICS security recommendations. |
DS 7-111 | Chemical Process Industries and sub-occupancy standards A to H | Interim revision. • Includes a new section and guidance for natural hazards events in chemical plants. • Added new windstorm recommendations applicable to process structures, vessels, piping and equipment with emphasis on insulation and asset integrity elements. |
DS 8-1 | Commodity Classification | Interim revision. • Added guidance on how to treat partial packaging in Section 2.2.8.1.2. • Added guidance on how to treat wooden crates for external packaging in Section 2.2.8.4. • Added guidance for encapsulated product in Section 2.2.8.5. |
DS 8-21 | Roll Paper Storage | Interim revision. • Added pre-incident plan recommendations to human element in Section 2.4. • Added supporting material related to on-end storage of RP 1 in Section 3.1.2.1 and Section 3.3. • Added definition of semi-standard array to Appendix A. |
DS 8-34 | Protection for Automatic Storage and Retrieval Systems | Interim revision. • A new ceiling sprinkler system design for ceiling heights up to an d including 30 ft (9.1 m) was added in the Final Extinguishment section for top-loading ASRS storage arrangements. • Added guidance on the intended goal of an adequately vented open-top container to Section 2.2.4 and Appendix A. • New figures were added to Section 2.3.6 to clarify that the recommended mezzanines did not have to extend along the entire perimeter of the storage array. |
DS 9-3 | USA and Canada (excl. Puerto Rico) Cost Trends | Updated as of January 2023. |
DS 9-10 | Rest of World Cost Trends | Updated as of January 2023. |
DS 10-1 | Pre-Incident and Emergency Response Planning | Interim revision. • Minor editorial changes were made. |
DS 13-17 | Gas Turbines | Interim revision. • Added recommendations to provide continuous online turbine rotor wheel space or disc-cavity temperature alarm for elevated temperatures. • Added recommendations to provide independent backup power systems for lubrication pumps and guidance on backup battery capacity to align with Data Sheet 13-3, Steam Turbines. • Added a recommendation to manually rotate a hot rotor to prevent rotor bowing when no lube oil or turning gear is available. |